Find help with asbestos inspections and registers for Melbourne properties.

Asbestos air monitoring and clearance certificates

When Victorian law requires air monitoring during asbestos removal, who can issue a clearance certificate and what it must state before reoccupation.

After licensed asbestos removal in Victoria, the area cannot be reoccupied until an independent person has inspected it and issued a clearance certificate, unless the job was only non-friable material of 10 square metres or less. For friable (Class A) removal indoors, air monitoring is also required before, during and at the end of the work, and the final readings inside the enclosure must be below 0.01 fibres per millilitre.

Illustrative photo for Asbestos air monitoring and clearance certificates

Monitoring and clearance work enquired about here goes to independent hygienists and consultants who quote and carry it out; read how this site works for details.

Who has to arrange monitoring and clearance?

The person who commissioned the removal work arranges both, not the removalist. That is usually the building owner, managing agent, builder or project manager. There is one exception: where removal is done at domestic premises used solely for domestic purposes and the owner commissioned it, the licensed removalist must obtain the clearance certificate.

The clearance inspection must be done by an independent person. WorkSafe’s removal compliance code says this person must be independent of the removalist and the licence holder doing the work and of whoever commissioned it, must have no conflict of interest, and must have the knowledge, skills and experience for the task. A project consultant who engaged the removalist cannot then issue the clearance.

When is air monitoring required?

Removal type Air monitoring under the OHS Regulations 2017 Clearance inspection and certificate
Class A (friable), indoors Required before work starts, throughout, and inside the enclosure at the end Required
Class A, outdoors with a risk to others Required Required
Class A by glove bag method Not required Required
Class B (non-friable), over 10 square metres Not required, but WorkSafe says the commissioner should consider it in or next to public areas Required
Non-friable only, 10 square metres or less Not required Not required

This kind of monitoring is called paraoccupational or static monitoring: pumps sit at fixed points just outside the removal area to check that the controls are keeping fibres in. Samples must be analysed by an approved laboratory, which means NATA approved for fibre counting, and the method follows the Safe Work Australia membrane filter guidance note.

What do the readings mean?

WorkSafe’s compliance code sets out action levels for monitoring results:

  • below 0.01 fibres per millilitre: no new controls needed
  • above 0.01 and up to 0.05: investigate the cause and tighten controls
  • above 0.05: stop the removal, notify WorkSafe, investigate, fix the controls, and do not restart until levels are at or below 0.01

A clearance certificate cannot be issued for Class A work if the final reading in the enclosure is 0.01 or more. The area is cleaned again and retested.

What the clearance certificate must say

The certificate must state that an independent person inspected the area and found no visible asbestos residue from the removal work in the work area or the area immediately around it, and, where monitoring was required, that the final airborne level was below 0.01 fibres per millilitre. WorkSafe recommends it also describe the scope of removal, so nobody mistakes asbestos that was deliberately left in place for a missed item. The endorsed laboratory report should be attached.

A good clearance inspection includes reading what was meant to be removed, inspecting every part of the work area (using lifting equipment for heights if needed), checking with the removalist, re-inspecting after any extra clean-up, and noting any remaining asbestos that later users should know about.

What the hygienist will need

  • The removal scope and the licensed removalist’s details and start date.
  • The asbestos control plan the removalist prepared.
  • Access before work starts to set out monitoring points, and at the end for the final inspection.
  • The building’s asbestos register or the demolition survey that defined the scope.

After clearance, a workplace register must be updated to show what was removed. Keep the certificate with the register; WorkSafe recommends keeping old certificates because they record what came out of the building.

Cost

Monitoring is priced per visit and per sample, and a clearance on a small Class B job usually costs less than a multi-day Class A job with daily pumps. No published source gives a reliable Melbourne range for monitoring alone, so compare written quotes; the Melbourne cost guide covers how to read them. Laboratory fibre counting is a separate line in most quotes.

What a careful hygienist will not do

  • Issue a clearance certificate for a job they or their employer commissioned.
  • Clear an area from photos sent by the removalist.
  • Sign a certificate before the laboratory results are back where monitoring was required.
  • Let barricades come down before the certificate has been handed to the removal supervisor.

Local angle

In the CBD and inner suburbs, removal can take place inside occupied buildings with neighbouring tenancies, shared lifts and air conditioning. That is where air monitoring around the enclosure earns its cost even when the law does not strictly require it, as WorkSafe suggests for Class B work near public areas. The CBD area page covers working in multi-tenant buildings.

What to do next

Tell the provider the removal class, the area, the removalist and the dates, then book monitoring or a clearance inspection well before the removal starts. The rules are in WorkSafe’s Removing asbestos in workplaces compliance code.

Send a job enquiry

Frequently asked questions

How long does a clearance inspection take?

A visual clearance of a small Class B job can often be done in one visit. Class A clearance waits for the final air monitoring results inside the enclosure, so allow for laboratory turnaround before the enclosure can come down and the area be reoccupied.

Does the clearance inspector have to take dust or wipe samples?

No. WorkSafe's removal code says the visual inspection for a clearance certificate does not require wipe samples or settled dust sampling. A hygienist may still take settled dust samples as an indication of cleanliness where they judge it useful, so ask whether your quote includes any.

Who gets the air monitoring results during Class A removal?

The person who commissioned the removal must pass the results to the licensed removalist as soon as they arrive. A copy must also be readily accessible to the health and safety representative and to employees or contractors affected by the work.

Where are the air monitoring pumps placed?

Generally in the middle of each sampling area, away from walls, corners and air conditioning inlets or exhausts. Where an enclosure and decontamination unit are used, WorkSafe lists the clean side of the decontamination unit, the changing area, any lunch room and the surroundings of the removal area, including above and below it.

Can an area be contaminated again after it is cleared?

Yes, if later work or damage disturbs asbestos. The certificate describes the area as it was when inspected. Where recontamination is a real possibility, WorkSafe says the inspector should add a statement explaining that risk and the circumstances behind it.